ECG-101 Digital Electrocardiograph

Features:

Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes                      
Click Image for Actual view
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA

 

Specification:

Single channel ECG machine with measurement

Manual/Auto/Arrhythmia Analysis Modes

Lead-off indicator

Built in rechargable NI-MH battery 12V (1500mAh)

Adapt to 110-230V, 50/60HZ AC power supply

Built in USB/RS232 interface (ECGNET software optional)

Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG

20×2 character LCD, USB is optional

 

ECG-102 Digital Electrocardiograph

Features:

Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes                     
 Click Image for Actual view
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA

Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF

 

Specifications:

Single channel ECG machine with measurement

Manual/Auto/Arrhythmia Analysis Modes

Built in rechargable NI-MH battery 12V (1500mAh)

Adapt to 110-230V, 50/60HZ AC power supply

Built in USB/RS232 interface (ECGNET software optional)

ECG waveform, 16 cases save/replay

Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG

320×240 graphic 3.8inch LCD, 16cases save/replay

 

ECG-120 Digital Electrocardiograph

Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes 
                     Click Image for Actual view
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%

Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF

Specifications:

Portable 12 channel ECG machine

Manual/Auto/Arrhythmia Analysis Modes

Alphabetic keyboard for patient information

Built in rechargable Li-Ion battery 14.4V (4400mAh)

Adapt to 110-230V, 50/60HZ AC power supply

Real-time ECG waveform, cases save/replay

Built in USB/RS232 interface (ECGNET software optional)

Package: 40cm×34cm×22cm   GW: 5.9KG   NW: 3.2KG

320×240 graphic 5.7inch LCD, 16cases save/replay

 
 

ECG-300G Digital Three Channel ECG

Features
High resolution thermal printing system, high precision
12 leads collection in phase as well as 3 leads printing in phase
Digital design and filter, baseline auto-adjustable.
LCD displays operation menu .DC/AC auto-exchange
Automatic measurement, analysis and diagnosis with high speed
Elegant and compact outlook, with inner handhold. 
               Click Image for Actual view

 

ECG-301 Digital Electrocardiograph

Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes 
                     Click Image for Actual view
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF

Specifications:

3 channel ECG machine with measurement

Manual/Auto/Arrhythmia Analysis Modes

80mm 3-ch recording with rhythm lead

Built in rechargable Li-Ion battery 14.4V (2200mAh)

Adapt to 110-230V, 50/60HZ AC power supply

Real-time ECG waveform, cases save/replay

Built in USB/RS232 interface (ECGNET software optional)

Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG

320×240 graphic 3.8 inch LCD

 

ECG-601 Digital Electrocardiograph

Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes 
                     Click Image for Actual view
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF

Specifications:

Portable 6 channel ECG machine

Manual/Auto/Arrhythmia Analysis Modes

112mm 3/6 channel format recording

Built in rechargable Li-Ion battery 14.4V (2200mAh)

Adapt to 110-230V, 50/60HZ AC power supply

Real-time ECG waveform, cases save/replay

Built in USB/RS232 interface (ECGNET software optional)

Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG

320×240 graphic 3.8 inch LCD

 

ECG-602 Digital Electrocardiograph

Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes         
             Click Image for Actual view
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF

Specifications:

Portable 6 channel ECG machine

Manual/Auto/Arrhythmia Analysis Modes

112mm 3/6 channel format recording

Built in rechargable Li-Ion battery 14.4V (2200mAh)

Adapt to 110-230V, 50/60HZ AC power supply

Real-time ECG waveform, cases save/replay

Built in USB/RS232 interface (ECGNET software optional)

Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG

320×240 graphic 5.7inch LCD, 16cases save/replay

 
 
 

And many more models contact Us for Inquiry and details.

 